Certification

Cyber Essentials

A UK government-backed baseline cyber-security certification based on a verified self-assessment.

On this page

Overview

Cyber Essentials is a certification scheme owned by the UK National Cyber Security Centre. IASME Consortium Limited manages it for NCSC as NCSC's exclusive delivery partner. NCSC describes it as the minimum cyber security standard the government recommends for organisations of any size. The scheme is built around five technical controls aimed at common internet-based attacks. Procurement Policy Note 014 says the scheme does not assure a specific product and is not designed for advanced, targeted attacks.

The basic certificate is a verified self-assessment. The applicant answers a question set. The Danzell question set says a board-level representative, business owner, or equivalent must approve the answers, or certification cannot be awarded. An assessor then marks the answers. NCSC's comparison table calls this independently verified. It is not the hands-on testing used for Cyber Essentials Plus. IASME's terms say the marking decision is not subject to an appeal.

The current technical standard is Requirements for IT Infrastructure v3.3. NCSC's resources page says v3.3 took effect on 2026-04-27. The question set answered in the portal is named Danzell. IASME's download page says Danzell was released on 2026-04-27, and the booklet is marked version 16.3, May 2026. The booklet is a preparation copy. The applicant must enter the answers on IASME's assessment platform.

Buyers see Cyber Essentials in UK public-sector procurement and in private supply-chain clauses. PPN 014, updated February 2025, tells central government departments, their executive agencies, non-departmental public bodies, and NHS bodies to require Cyber Essentials or Cyber Essentials Plus, or equivalent controls, on certain higher-risk contracts, and to require annual renewal where they do. The same note says the scheme must not be applied to every contract. A certificate names one legal entity, or a stated partial scope, and IASME's terms make it valid for 12 months from the date of issue.

Key facts

Issued by
A certification body appointed by IASME
Deliverable
A Cyber Essentials certificate for a defined organization and assessment scope.
Validity
12 months. IASME's scheme terms say the certificate is valid for 12 months from the date of issue. Where a contract requires the certificate, PPN 014 requires annual renewal.
Public registry
Yes. Check it before you ask the vendor.
Current version
Requirements for IT Infrastructure v3.3, effective 2026-04-27, assessed with the Danzell question set.
Applies to
  • All organizations
  • Government contractors

Scope

The applicant agrees the scope with the certification body before assessment. v3.3 says the scope should be the whole IT infrastructure used for the business, or a separately managed sub-set.

Whole or partial scope
Whole organisation means all networks, user accounts, and devices that access the organisation's data and services. A partial scope must be segregated with a firewall or VLAN. The Danzell question set says security groups, microsegmentation, and software-based methods do not create a compliant sub-set, and a software firewall cannot define the scope boundary.
What the requirements cover
v3.3 applies the requirements to in-scope devices and software that accept inbound connections from internet-connected devices, make outbound internet connections, or control the flow of data between those devices and the internet. The scope boundary must name the business unit, the network boundary, and the physical location.
End-user devices
v3.3 says a scope with no end-user devices is not acceptable. Devices owned by the organisation and issued to staff, volunteers, or trustees are in scope, including home and remote-working devices. User-owned devices that access organisational data or services are in scope, except devices used only for native voice, native text, or an MFA application.
Cloud services
v3.3 says cloud services that host the organisation's data or services cannot be excluded, and the organisation remains responsible for every control. Where the provider implements a control, the organisation must hold a contractual commitment, such as a clause or a security statement the contract points to. The applicant still configures the service, and cloud authentication must use MFA.
Out of scope by rule
The Danzell question set says development, testing, and penetration-testing networks must stay out of scope and must be separated by a firewall or VLAN. v3.3 puts student, customer, contractor, and MSP-administrator devices the organisation does not own out of scope, while accounts the organisation owns stay in scope even when a supplier uses them. The person named as responsible for in-scope IT must work for the applicant, not for the outsourced IT provider.
What the certificate shows
The certificate displays one legal entity, and extra entities can be listed only if they share the IT infrastructure and a board-level signatory for all of them. For a partial scope, Danzell says the certificate reads 'Partial Organisation, see certificate platform for details', with the scope description on the Blockmark platform. The exclusion list and the network inventory are not made public.

Types and levels

NCSC offers two certificates against the same five controls. The difference is how the controls are checked.

Cyber Essentials
The applicant completes the Danzell question set and an assessor marks it. IASME's FAQ says this level includes no vulnerability scan, and NCSC calls the result a baseline. IASME's terms say the certificate is valid for 12 months from the date of issue.
Cyber Essentials Plus
Plus uses the same requirements and adds independent technical testing by an assessor at an IASME-licensed certification body. IASME's question-set page says the Plus audit must be completed within 3 months of the last basic certificate, and that the two can be done at the same time. PPN 014 describes Plus as the version to use when the cyber risk is higher.

Key requirements

Requirements for IT Infrastructure v3.3, effective 2026-04-27, sets five technical controls. Backups are recommended in that document and are not a requirement. The Danzell question set marks some 'no' answers as an automatic fail.

Firewalls
Every in-scope device needs a correctly configured firewall or equivalent, with default administrative passwords changed or remote administration disabled. The administrative interface must not be reachable from the internet unless there is a documented need and it is protected by MFA or by an IP allow list plus a managed password. Unauthenticated inbound connections are blocked by default, rules are documented and removed when unused, and devices on untrusted networks need a software firewall.
Secure configuration
The organisation removes or disables unnecessary accounts and software, changes default or guessable passwords, disables auto-run, and authenticates users before they reach organisational data or services. A credential that only unlocks a device is at least 6 characters. Where the vendor allows it, guessing is limited to no more than 10 attempts in 5 minutes, or the device locks after no more than 10 failures.
Security update management
In-scope software must be licensed and supported, with automatic updates on where possible. Fixes the vendor calls critical or high risk, fixes with a CVSS v3 base score of 7 or above, and unrated fixes must be installed within 14 days, and Danzell marks a 'no' to that question as an automatic fail. Unsupported software must be removed or placed in a sub-set with no internet access, or whole-organisation certification is not available.
User access control
The organisation approves accounts, uses unique credentials, removes unused accounts and privileges, requires MFA for cloud services, and keeps administrative accounts off email and web browsing. Passwords are protected against guessing and are at least 12 characters, or at least 8 with a deny list, unless MFA is used, in which case the password element is at least 8 characters. Danzell treats a false claim that a cloud service has no MFA option as an automatic fail.
Malware protection
Every in-scope device must have an active malware-protection mechanism, kept up to date as the vendor instructs. One option, for Windows or MacOS including servers, desktops, and laptops, is anti-malware that blocks malware, malicious code, and connections to malicious websites. The other option, for any in-scope device, is application allow listing by code signing: applications are approved before deployment, the approved list is kept current, and unsigned or invalidly signed applications cannot be installed.

Certification process

  1. Agree the scope

    The applicant sets the boundary and agrees it with the certification body before assessment starts. A partial scope needs a written reason. Excluded networks must be segregated by a firewall or VLAN.

  2. Prepare against the current set

    The applicant uses Requirements v3.3 and the Danzell question set, version 16.3. The downloadable booklet is for preparation. Certification uses the answers entered on IASME's platform, and every question has to be answered.

  3. Apply through IASME or a certification body

    NCSC describes a self-led route, registered with IASME and marked by an assessor, and a supported route that uses a certification body licensed by IASME. IASME's terms define the certificate as issued by a certification body appointed by IASME. In both routes the assessor marks the submitted answers.

  4. Submit with board approval

    A board-level representative, business owner, or equivalent approves the answers. IASME's terms require the questionnaire to be submitted within six months of IASME sending it. A later submission is not assessed.

  5. Assessor marks the answers

    The assessor marks the questionnaire against the requirements. IASME's terms allow one further assessment at no extra charge if the applicant resubmits within 48 hours of the failure notice, and a later attempt is a new application. The terms say the result cannot be appealed.

  6. Certificate is issued

    If the assessment passes, the certification body issues a certificate valid for 12 months from the date of issue. IASME may publish the organisation's name and, where relevant, the scope. The question answers stay confidential under the terms.

Renewal and maintenance

  • IASME's terms say the certificate is valid for 12 months from the date of issue. The FAQ says both Cyber Essentials and Cyber Essentials Plus expire after 12 months, and that IASME removes organisations that have not certified in the past year from the certified list. Recertification means answering the question set again. IASME says some questions change between years.
  • IASME's FAQ says it emails a reminder about a month before renewal is due. PPN 014 Q7 says the certificate is assurance only at the time of testing, and that an organisation that stops patching or holding its configuration can fall out of compliance in less than a year.
  • The submission window is six months from the date IASME sends the questionnaire. One failed attempt can be resubmitted within 48 hours under clause 2.6 of the terms. IASME's FAQ describes that window as two working days.
  • Where a contract requires the certificate, PPN 014 says the supplier must renew it annually for the life of the contract. Evidence is required before contract award, and again at the point data is passed if the certificate has lapsed during a renewal.

Enforcement and penalties

  • PPN 014, published on 17 February 2025, tells in-scope organisations to apply its provisions from 24 February 2025. It applies to central government departments, their executive agencies, non-departmental public bodies, and NHS bodies. It replaces PPN 09/14 and PPN 09/23. The note does not set a fine or other penalty. It is an instruction to those contracting authorities.
  • Paragraphs 12 and 14: where a supplier handles citizen or government-staff personal information, supplies ICT that stores or processes data at OFFICIAL, or handles information about the day-to-day business of government, the contracting authority must require technical controls. The note says the usual method is a Cyber Essentials or Cyber Essentials Plus certificate, renewed annually for the life of the contract, or equivalent controls demonstrated another way.
  • Paragraphs 15, 20, and 21, and Annex C Q10: the requirement must be relevant to the contract and must not be applied to every contract. Equivalents must be accepted. Q10 cites section 56 of the Procurement Act 2023 and says that, for a claim of equivalence to Cyber Essentials Plus, a technically competent independent third party must verify the controls in all cases. Q5 requires evidence of the certificate, or an equivalent, before contract award. Paragraph 16 says that evidence is essential when data is passed to the supplier. A contracting authority may, as an exception, start work while an expired certificate is being renewed, but the supplier must hold the certificate or an equivalent when data is passed.
  • Paragraph 26: suppliers on Crown Commercial Service G-Cloud agreements must meet the Government's Cloud Security Principles. Holding Cyber Essentials is encouraged and is not a requirement of that commercial agreement. Paragraph 17 says the scheme does not assure the specific product or service being bought. Q9 says an ISO/IEC 27001 certificate does not by itself meet Cyber Essentials, because the five controls are not always in the ISO scope and are not usually tested.

Vendor due diligence

What to request

  • Search the IASME certificate search that NCSC links, by the legal name and by the certificate number. Record the level, certification date, and expiry. The search covers certificates issued in the last 12 months. IASME's Supplier Assurance Tool terms, effective 2026-10-05, say that tool must not be the only check, and that there can be a delay before a new certificate appears. Ask for the certificate itself.
  • Match the legal entity on the certificate to the contracting party. The Danzell question set allows one name, plus a trading name, and lists any other legal entities only if they share the infrastructure and the board signatory. Entities that are not listed are not covered.
  • If the certificate says partial organisation, open the scope description on the certificate platform. Danzell says that description is held on Blockmark. Ask separately for the excluded networks. Danzell says the exclusion list in A2.2.1, and the network inventory, are not made public.
  • Confirm the scope includes the end-user devices and the cloud services that will touch your data. v3.3 does not allow either to be left out. Ask which controls the cloud provider implements and for the contract clause or security statement the applicant relied on.
  • Ask which requirements version and which question set were used. For an assessment now, that is v3.3, effective 2026-04-27, and Danzell v16.3. Ask for the assessor's feedback on any answers that were marked non-compliant, and whether the pass followed a resubmission.
  • Check the issue date. IASME's terms give 12 months from issue. PPN 014 says the assurance is only as of the test, so ask whether patching and configuration are still operating as answered, especially if the certificate is many months old.
  • Do not treat an ISO/IEC 27001 certificate, a G-Cloud listing, or a pending application as a Cyber Essentials certificate. IASME's Supplier Assurance Tool terms say an application that has not yet been granted is confidential.
Search the official registry

Red flags

  • A badge or a PDF certificate that does not match a current entry on the IASME certificate search, or a certificate whose legal name is a parent or a sister company of the supplier.
  • A partial-scope certificate offered for a service that sits in an excluded network. The exclusion list is not on the public certificate.
  • A scope boundary drawn with a software firewall, a cloud security group, or microsegmentation. Danzell says a sub-set must be a firewall or a VLAN.
  • Cloud services, or staff laptops and phones, described as out of scope. v3.3 says both are in scope.
  • Unsupported software still in an internet-connected part of the scope. Danzell treats that as incompatible with whole-organisation certification, and the 14-day high-risk update question as an automatic fail if the answer is no.
  • A certificate older than 12 months from its issue date, or a claim that a lapsed certificate is 'in renewal' while data is already being shared. PPN 014 allows that exception only until the point data is passed, and only as a risk decision by the contracting authority.
  • An ISO/IEC 27001 certificate, or a statement that the organisation is on G-Cloud, presented as Cyber Essentials. PPN 014 says neither one is a substitute.
  • The person named as responsible for the in-scope systems is an employee of the outsourced IT provider. Danzell says that person must belong to the applicant organisation.

Terminology

Use this wording in contracts, security questionnaires, and trust center copy.

Correct

The company holds a current Cyber Essentials certificate.

Incorrect
  • NCSC certified

FAQ

Is Cyber Essentials an audit?

NCSC calls the basic certificate a verified self-assessment that an assessor marks, and its table marks it as independently verified. IASME's FAQ says it includes no vulnerability scan, and the hands-on testing is Cyber Essentials Plus. IASME's terms say the marking decision cannot be appealed.

How long does the certificate last?

IASME's terms say it is valid for 12 months from the date of issue. The FAQ says certificates expire after 12 months and that organisations that have not certified in the past year are removed from the certified list. Recertification is a new set of answers, not an extension of the old form.

What does a partial-scope certificate hide?

Danzell says the certificate will read 'Partial Organisation, see certificate platform for details', and that the scope description is on the Blockmark platform. The description of excluded networks, and the network list, are not made public. Ask the supplier for those exclusions and check that your data is on the in-scope side of the firewall or VLAN.

Which question set is current?

Danzell, which IASME's download page says was released on 2026-04-27. The preparation booklet is marked version 16.3, May 2026. It is answered against Requirements for IT Infrastructure v3.3, effective 2026-04-27.

Does every UK government contract require it?

No. PPN 014 requires the contracting authorities it covers to use Cyber Essentials or Plus, or an equivalent, for the contracts in paragraph 12, and it tells them not to apply the scheme to every contract. G-Cloud does not require it, equivalents are allowed, and a Plus equivalent must be independently verified.

Does the certificate include cyber insurance?

NCSC's resources page says a UK organisation with turnover under £20 million, whose certificate covers the whole organisation, is entitled to cyber liability insurance arranged by IASME, with a stated liability limit of £25,000. The Danzell question set says the insurance questions do not change the assessment result. The insurance is not part of the technical assessment.

Companies in the directory

Companies in our directory that list Cyber Essentials on their trust center. This is not a count of every organization that has it, and trustlists has not verified the claims.

0 companies

No company in the directory mentions Cyber Essentials yet.

Add a trust center
Sources10 references
  1. ncsc.gov.uk

    NCSC describes Cyber Essentials as a verified self-assessment certification and states that certification renews annually.

  2. ncsc.gov.uk

    Requirements for IT Infrastructure v3.3 are effective from 27 April 2026. The resources page also lists the Cyber Essentials Plus Test Specification v3.2, dated 28 April 2025, and states the whole-organisation cyber liability insurance entitlement for a UK organisation with turnover under £20 million, with a £25,000 liability limit. NCSC's certificate-search link points to IASME.

  3. ncsc.gov.uk

    Requirements for IT Infrastructure v3.3, April 2026. Five controls and their obligations, including the 14-day update rule, cloud MFA, firewall rules, malware options, and password and lockout thresholds. Scope rules: whole infrastructure or a segregated sub-set agreed before assessment; end-user devices required; cloud services cannot be excluded; BYOD and third-party device rules; backups are recommended and are not a requirement.

  4. iasme.co.uk

    IASME, as NCSC's delivery partner, says the current question set is Danzell, released on 27 April 2026, and that Cyber Essentials is annually renewable. The Plus audit must be completed within 3 months of the last basic certification, and the two can be completed at the same time.

  5. iasme.co.uk

    Danzell question set, version 16.3, May 2026. All questions must be answered on IASME's platform and approved by a board-level representative, business owner, or equivalent. Partial-scope certificate wording, Blockmark scope text, non-public exclusion and network lists, firewall-or-VLAN sub-sets, automatic fail on the 14-day update questions and on a false 'no MFA' cloud answer, unsupported software rule, and the rule that the named IT lead must belong to the applicant.

  6. iasme.co.uk

    Scheme terms: NCSC owns Cyber Essentials and Cyber Essentials Plus. IASME Consortium Limited is the exclusive partner. A certification body appointed by IASME issues the certificate. The questionnaire must be submitted within six months of being sent. The certificate is valid for 12 months from the date of issue. One free resubmission is allowed within 48 hours of a failure notice. There is no appeal. Assessment answers are confidential. IASME may publish the name and, if relevant, the scope.

  7. iasme.co.uk

    IASME FAQ: basic Cyber Essentials has no vulnerability scan. A board member signs a declaration. Both certificates expire after 12 months. The applicant has six months from application to submit. If the assessment fails, IASME allows two working days to correct and resubmit. Recertification requires the questions to be answered again. IASME emails a reminder about a month before renewal. Plus can reuse a basic certificate achieved less than 3 months earlier.

  8. iasme.co.uk

    IASME certificate search verifies Cyber Essentials and Cyber Essentials Plus. Search by name or certificate number for certificates issued in the last 12 months. The results table has company name, certificate reference, level, certification date, expiry, and a score column. The page does not define the score.

  9. firststep.iasme.co.uk

    IASME Supplier Assurance Tool terms, effective 2026-10-05. The tool must not be the only verification of a certificate. Information can be incomplete, and a new certificate can be delayed in appearing. The user should ask the supplier for a valid certificate. An application that has not yet been granted is confidential.

  10. gov.uk

    PPN 014, published 17 February 2025, in force for contracting authorities from 24 February 2025. Scope of bodies, contract characteristics, annual renewal, equivalents and Procurement Act 2023 section 56, timing of evidence, G-Cloud exception, no product assurance, not designed for advanced attacks, ISO/IEC 27001 is not a substitute, and assurance is only at the time of testing. The note states no fine.

History

Last reviewed 2026-11-27 by trustlists research.

  1. Initial primary-source reference published.